Head of the electrical engineering laboratory. Job Description of the Head of Etl II. Job responsibilities

Instructions for the head of the electrical laboratory | ELECTROlab. Good day, dear friends! Today I am publishing an example of a job description for the head of an electrical engineering laboratory, t. I hasten to warn you that for each specific situation it will be necessary to make a number of changes to the content of the instructions. I hope the article will be useful to you. JOB DESCRIPTION IS APPROVED BY THE DIRECTOR.

MP "Vodokachka"______________D. D. Director "______" _____________2. Head of the electrical engineering laboratory. I. GENERAL PROVISIONS1.

The head of the electrical engineering laboratory belongs to the category of managers. A person with a higher technical education, work experience as electrical personnel for at least 3 years, who has passed a medical commission and knowledge testing of the “Rules for the Technical Operation of Consumer Electrical Installations” (PTEEP), Interindustry Rules for Labor Protection (Safety Rules) is appointed as the head of the electrical laboratory. during the operation of electrical installations (MPOT (PB)), “Rules for the construction of electrical installations” (PUE) in the Rostechnadzor commission for group V on electrical safety. (if ETL is up to 1. V, then for group IV)3. The head of the electrical laboratory reports to... (for example, the chief engineer of the enterprise). Released and appointed to the position by order of the director of the enterprise, on the recommendation of... (for example, the head of the workshop for repair and maintenance of power equipment and in agreement with the chief power engineer). The head of the electrical engineering laboratory must know: · regulations, instructions, orders and other guidance, methodological and regulatory documents relating to the operation and repair of automation equipment, protection and instrumentation of the relevant equipment; · rules of technical operation, diagrams, operational characteristics and principles of operation of equipment of automatic devices, technological protections and instrumentation of the electrical laboratory; · operational standards for equipment operation and testing; · domestic and foreign experience in the field of electrical engineering laboratory activities; · basics of economics, organization of production, labor and management; · basics of labor legislation; · rules on labor protection, environmental protection, industrial sanitation and fire safety.

1.1. This job description defines the functional duties, rights and responsibilities of the head of the electrical laboratory (hereinafter referred to as the “Employee”). Based on these characteristics, a job description for the head of an electrical laboratory is developed, containing the rights and responsibilities of the employee. Job description of an electrician in an electrical laboratory, etc. For example, instruction 2 (official head of ETL).

II. OFFICIAL RESPONSIBILITIES The head of the electrical engineering laboratory is obliged to: · ensure the unconditional fulfillment of the goals and objectives set for the electrical engineering laboratory (ETL); · timely submit for approval to the chief power engineer (engineer) plans and schedules for testing electrical equipment, checking relay protection, checking protective grounding for the next year, in accordance with PTEEP, MPOT (PB) and PUE, these plans and schedules must be linked to planned repairs technological equipment; · conduct classes on PTEEP, MPOTT (PB) and PUE for training electrical personnel for the admission group; · carry out work on setting up relay protection for electric motors of submersible pumps at all production facilities; · determine possible minimum settings for relay protection of main facilities, record them on the settings map and coordinate with energy supply organizations to ensure selectivity in the operation of protection; · timely conduct scheduled and extraordinary briefings to subordinate personnel in full compliance with MPOT (PB), PTEEP and instructions; · take part in the preparation of annual requests for the purchase of necessary devices and timely updating of those in use; · organize training of electrical technical personnel in advanced labor methods and rules for PTEEP and MPOT (PB); · control the conduct of tests and the correctness of protocols and other technical documentation; · issue orders and instructions for carrying out work in electrical installations with voltages up to and above 1 0. V and for carrying out electrical testing of electrical equipment in accordance with PTEEP and MPOT (PB); · organize timely verification of operated devices in ETL; · check the execution of test reports.

Amoxil for children instructions · Sophora Japanese tincture for internal use instructions · job description of the head of the electrical laboratory · introductory instructions for. Therefore, carefully read the job description: Head of Electrical Engineering Laboratory for items of responsibilities where specific areas are indicated. Job description of the head of the laboratory (bureau) for the organization Job description of the head of the electrical laboratory. Job description for the head of an electrical laboratory. According to the portal obzorzarplat.ru. ECTS. Head of the electrical engineering laboratory. Other job titles.


Typical labor safety instructions for repair electricians. Job description for the head of an electrical laboratory. Job description for the head of an electrical laboratory. A large selection of sample job description forms for various.

III. RIGHT The head of an electrical laboratory has the right to: · disconnect existing electrical equipment that has not passed the test; · petition the head of the organization to encourage workers, or to punish workers who have committed violations of production and labor discipline; · suspend from work ETL personnel who violated PTEEP and MPOT (PB); · individually carry out inspections of electrical installations with voltage up to and above 1 0. V. IV. RESPONSIBILITY The head of the electrical laboratory is responsible: · for improper performance or failure to fulfill his job duties provided for in this job description - within the limits determined by the current labor legislation of the Russian Federation; · for offenses committed in the course of carrying out its activities - within the limits of the current administrative, criminal and civil legislation of the Russian Federation; · for causing material damage - within the limits of the current administrative, criminal and civil legislation of the Russian Federation. Compiled by: Head of workshop. Agreed by: Deputy Director for Technical Affairs. Chief power engineer. Deputy Director for Legal and Personnel Issues.

Head of HR Department. Head of the sector for organization and accounting of wages and working hours. I have read the instructions: “_____”__________2.

JOB DESCRIPTION FOR THE HEAD OF THE ELECTRICAL ENGINEERING LABORATORY

I. General provisions

  1. The head of the electrical engineering laboratory belongs to the category of managers.
  2. A person with a higher professional (technical) education and work experience in an electrical laboratory of at least 3 years (at a power plant for at least 5 years) is appointed to the position of head of an electrical engineering laboratory.
  3. The head of the electrical engineering laboratory is appointed to the position and dismissed from the position in the manner prescribed by law by order of the head of the organization upon the recommendation of _________________________.
  4. The head of the electrical laboratory reports directly to __________________________.
  5. During the absence of the head of the electrical laboratory (vacation, illness, etc.), his official duties are performed by an employee appointed in the prescribed manner, who acquires the corresponding rights and bears responsibility for non-fulfillment or improper performance of duties.
  6. The head of the electrical engineering laboratory must know:
    - decrees, orders, orders and other guidance, methodological and regulatory documents relating to the operation and repair of automation equipment, protection and instrumentation of the relevant equipment;
    - rules of technical operation, diagrams, operational characteristics and principles of operation of equipment of automatic devices, technological protections and instrumentation of the electrical laboratory;
    - operational standards for equipment operation and testing;
    - domestic and foreign experience in the field of electrical engineering laboratory activities;
    - basics of economics, organization of production, labor and management;
    - basics of labor legislation;
    - rules on labor protection, environmental protection, industrial sanitation and fire safety.
  7. _________________________________________________________________.

II. Job responsibilities

  1. Manages the electrical laboratory, ensuring the operation and repair of automation and relay protection equipment, control and measuring instruments of the relevant energy equipment, organizes the provision of equipment with the equipment and measuring instruments necessary for testing and monitoring its operation.
  2. Manages the ongoing and periodic monitoring of the operation of power plant equipment.
  3. Organizes setup, adjustment and ensures the normal operation of all devices, equipment and instruments under the jurisdiction of the laboratory, draws up instructions and instructions for their maintenance.
  4. Manages the preparation and participates in testing of equipment assigned to the laboratory.
  5. Monitors the timely registration of test results and maintenance of technical documentation.
  6. Monitors the condition of laboratory equipment and workplaces of laboratory workers, takes measures to eliminate deficiencies.
  7. Ensures the introduction of new equipment, the dissemination of advanced techniques and work methods in the laboratory.
  8. Monitors employees' compliance with labor protection, environmental protection, industrial sanitation and fire safety rules.
  9. _________________________________________________________________.
  10. _________________________________________________________________.

III. Rights


The head of the electrical engineering laboratory has the right:
  1. Participate in the discussion of draft decisions of the head of the organization.
  2. Dispose of the property and funds entrusted to him in compliance with the requirements determined by legislative and regulatory legal acts and the Charter of the organization.
  3. Familiarize yourself with draft decisions of the organization’s management concerning its activities, and demand that the organization’s management provide assistance in the performance of their official duties and rights.
  4. Submit proposals for the management's consideration to improve the organization's activities on relevant issues, as well as on the hiring, transfer and dismissal of employees, on encouraging distinguished employees and on applying disciplinary sanctions to employees who violate labor discipline.
  5. Sign and endorse documents within your competence.
  6. Interact with the heads of the organization’s structural divisions, obtain information and documents necessary to perform their job duties.
  7. Initiate and conduct meetings on organizational, financial and economic issues.
  8. Require the head of the organization to provide assistance in the performance of his official duties.
  9. _________________________________________________________________.
  10. _________________________________________________________________.

IV. Responsibility


The head of the electrical engineering laboratory is responsible for:
  1. Failure to perform or improper performance of one’s job duties as provided for in this job description - within the limits determined by the current labor legislation of Ukraine.
  2. Causing material damage - within the limits determined by the current labor and civil legislation of Ukraine.
  3. Offenses committed in the course of carrying out their activities - within the limits determined by the current administrative, criminal, and civil legislation of Ukraine.
  4. _________________________________________________________________.
  5. _________________________________________________________________.

Job head of an electrical laboratory vacancy head of an electrical laboratory in Moscow. Vacancy for head of an electrical laboratory from a direct employer in Moscow, job advertisement for head of an electrical laboratory in Moscow, vacancies for recruitment agencies in Moscow, looking for a job as head of an electrical laboratory through recruitment agencies and from direct employers, vacancies for head of an electrical laboratory with and without work experience. Advertising site for part-time work and work Avito Moscow job vacancy head of an electrical laboratory from direct employers.

Work in Moscow as head of an electrical engineering laboratory

Website job Avito Moscow job latest vacancies head of electrical laboratory. On our website you can find a highly paid job as head of an electrical laboratory. Look for a job as head of an electrical engineering laboratory in Moscow, view vacancies on our job site - a job aggregator in Moscow.

Avito vacancies Moscow

Jobs as head of an electrical laboratory on a website in Moscow, vacancies for head of an electrical laboratory from direct employers in Moscow. Jobs in Moscow without work experience and highly paid ones with work experience. Job openings for head of electrical engineering laboratory for women.

1. GENERAL OCCUPATIONAL SAFETY REQUIREMENTS

1.1. This Instruction provides basic labor protection requirements for the head of an electrical laboratory.

1.2. The head of the electrical laboratory must perform his duties in accordance with the requirements of these Instructions.

1.3. The head of an electrical engineering laboratory may be exposed to the following dangerous and harmful production factors:

increased noise and vibration levels;

dangerous voltage level in an electrical circuit, the closure of which can occur through the human body;

increased level of static electricity;

increased surface temperature of the product and equipment;

fire and explosion hazard;

driving mechanisms and machines.

1.4. Persons at least 18 years of age who have been trained in the appropriate program and certified by the qualification commission in the prescribed manner and have received permission to work independently are allowed to work as the head of an electrical laboratory.

1.5. The head of the electrical laboratory is provided with special clothing and safety footwear in accordance with current standards.

1.6. The head of the electrical laboratory must have an appropriate electrical safety group.

1.7. The head of an electrical laboratory must know and strictly comply with the requirements for labor protection, fire safety, and industrial sanitation.

1.8. The head of the electrical laboratory notifies his immediate supervisor about any situation that threatens the life and health of people, about every accident that occurs at the workplace, about a deterioration in his health, including the manifestation of signs of an acute illness.

1.9. When carrying out measurements, fire safety requirements must be met in accordance with the requirements of GOST 12.1.004-91 and the Fire Regulations in the Russian Federation.

1.10. Work with harmful and explosive substances must be carried out with the ventilation systems turned on and using personal protective equipment.

1.11. The presence of unauthorized persons in the working space of the equipment during its measurements is not allowed.

1.12. Repair of equipment and maintenance of automation and measuring instruments must be carried out in accordance with the technical documentation of the organization that developed the technological process.

1.13. The head of an electrical engineering laboratory must undergo training in labor protection in the form of: introductory briefing, initial briefing in the workplace and special training within the scope of the training program for the profession, including labor protection issues and requirements for job responsibilities in the profession.

Induction training is carried out by an employee of the labor protection service or an employee replacing him with all those hired according to a program approved by the employer and agreed upon with the trade union committee or other representative body of workers.

Initial briefing at the workplace is carried out by an official determined by order individually before the start of the employee’s production activities under the occupational safety program for the profession.

1.14. The head of the electrical engineering laboratory must know:

laws and other regulatory legal acts of the Russian Federation, methodological and regulatory documents relating to the operation and repair of automation equipment, protection and instrumentation of relevant equipment;

rules of technical operation, diagrams, operational characteristics and principles of operation of equipment of automatic devices, technological protections and instrumentation of the electrical laboratory;

operational standards for equipment operation and testing;

First aid instructions;

be able to provide first aid to victims.

1.15. Smoking and eating are permitted only in areas specially designated for this purpose.

2. OCCUPATIONAL SAFETY REQUIREMENTS BEFORE STARTING WORK

2.1. Wear the protective clothing, safety shoes and personal protective equipment required by the relevant standards. Overalls must be fastened.

2.2. Measurements and tests should be carried out according to programs and methods, technical conditions. Measurements and tests of electrical equipment and electrical installations newly put into operation are carried out in accordance with the standards provided for by the rules for the construction of electrical installations (PUE), the requirements of manufacturing organizations, the requirements of standards, and measurements and tests of existing electrical installations of electrical equipment - to the extent of the requirements of the norms and rules of their operation . Testing facilities (electrical laboratories) must be registered with Rostechnadzor.

2.3. Admission under orders or orders to carry out measurements and tests is made only after other teams working on the equipment to be tested or measured have left the workplace and they have handed over the orders or reported the completion of work as per the order.

2.4. The preparation of the object and measuring instruments for testing or measurements should be carried out in the absence of voltage and residual charge on them. The operating voltage and residual charge must also be removed from other objects (other parts of test and measurement objects), unless touching or voltage to them is excluded, or these objects must be fenced off during preparation and testing.

2.5. The assembly of test and (or) measuring circuits should be carried out in the absence of voltage and residual charge at the test and (or) measurement object or part thereof, at the means of measuring and (or) testing.

2.6. The test or measurement site must be fenced.

2.7. Safety signs (posters) with explanatory inscriptions should be hung on fences, not lower than in the locations of parts of test objects (measurements). Safety signs and barriers should be removed only after the test (measuring) load and residual charge have been removed.

2.8. Prepare the protective equipment and devices necessary to perform the work.

2.9. Do not allow untrained or unauthorized persons to perform your work.

2.10. Check the lighting condition of the workplace.

2.11. Check the serviceability of grounding, the presence and serviceability of fire-fighting equipment, the availability of personal protective equipment, the operation of ventilation units, and electrical equipment. All exposed and accessible moving parts of the equipment must be protected with secured guards.

2.12. Check the availability of a first aid kit, primary fire extinguishing equipment, and personal protective equipment.

2.13. Report all detected malfunctions of equipment, inventory, electrical wiring and other problems to your immediate supervisor and begin work only after they have been eliminated.

3. OCCUPATIONAL SAFETY REQUIREMENTS DURING WORK

3.1. Work only in working clothing and safety shoes and use personal protective equipment.

3.2. Carry the tool to the workplace only in a special bag or box.

3.3. In electrical installations, it is not allowed for people, mechanisms and lifting machines to approach unprotected live parts that are energized at a distance of up to 1 kV on an overhead line - 0.6 m, from mechanisms and lifting machines - 1 m.

3.4. Work with guards, blocking and other devices in place and in good working order. When carrying out electrical measurements and tests, direct contact of the worker with components and elements that have a dangerous or harmful effect must be eliminated.

3.5. Maximum permissible values ​​of touch voltages and currents during emergency operation of industrial electrical installations with voltages up to 1000 V with a solidly grounded or insulated neutral.

3.6. Dangerous areas at work sites and workplaces must be marked with appropriate safety signs.

3.7. When carrying out tests (measurements), the connection of measuring instruments, as well as the installation and removal of electric meters to check them, are carried out after the voltage has been removed.

3.8. Connecting and disconnecting test and measurement equipment at test (measurement) objects that have moving parts must be performed after these parts have come to a complete stop.

At the same time, it is necessary to prevent the unintended launch of such objects during connections.

3.9. Connect the connecting wire to the equipment being used (measured) or to a cable (bus, wire, etc.) and disconnect it only after they are grounded.

3.10. Before each switching on of the test (measuring) installation it is necessary:

Remove unauthorized persons;

Warn all team members about the voltage supply with words;

Remove the ground from the terminal of the test installation and apply a voltage of 380/220 V to it.

3.11. When applying the test voltage, the operator must stand on an insulating mat.

3.12. From the moment the voltage is applied, it is not allowed to make any reconnections on the test (measuring) circuit.

3.13. Before starting tests or measurements, it is prohibited for persons to be near the test (measuring) device or to touch its live parts that are under the test (measuring) voltage of the electrical installation.

3.14. The supply of test (measuring) voltage to the test (measurement) object is allowed after the removal of personnel from the test (measuring) field and prior notification with an audio signal.

3.15. During the period of testing (measurements) on equipped electrical installations that are under test (measuring voltage), it is not allowed to carry out repair, installation and adjustment work on them.

3.16. Short-term electrical contact of measuring (test) instruments with the test (measurement) object is carried out with flexible wires ending in probes.

3.17. All measurements (tests) must be carried out in the presence of warning (prohibiting) posters.

3.18. Not allowed:

Smoking;

Performing work using open fire;

The use of electric tools that produce sparks and electrical lighting fixtures in an explosive design.

3.19. Do not eat in the workplace.

3.20. Work in sufficient light.

3.22. Place foreign objects and tools at a distance from moving vehicles and machinery.

3.23. Do not clutter the workplace, passages and passages leading to it, passages between equipment, racks, passages to control panels, switches, evacuation routes and other passages with empty containers, equipment, excess supplies of materials, etc.

3.24. Follow the rules of movement in the premises and on the territory of the organization, use only designated passages.

3.25. If any violations are detected, turn off the equipment and notify the supervisor.

4. OCCUPATIONAL SAFETY REQUIREMENTS IN EMERGENCIES

4.1. If an equipment breakdown occurs that threatens an accident at the workplace: stop its operation, as well as the supply of electricity, gas, water, raw materials, product, etc.; report the measures taken to your immediate supervisor (the person responsible for the safe operation of the equipment) and act in accordance with the instructions received.

4.2. In an emergency: notify surrounding people of the danger, report to your immediate supervisor about the incident and act in accordance with the emergency response plan.

4.3. In case of a chemical burn, immediately rinse the affected area with plenty of running cold water from the tap, rubber hose or bucket for 15-20 minutes. If acid or alkali gets on the skin through clothing, you must first wash it off with water from the clothing, and then rinse the skin.

4.4. If splashes of alkali or vapors get into the eyes or mouth, rinse the affected areas with plenty of water and then with a solution of boric acid (0.5 teaspoon of acid per glass of water).

4.5. In the event of a fire, you must:

Stop working;

Disable the equipment being used;

Call the fire brigade, inform the work manager and begin extinguishing the fire using available means.

4.6. When there is a fire at electrical installations, use carbon dioxide and powder fire extinguishers.

4.7. If there are wounds, apply a bandage; if there is arterial bleeding, apply a tourniquet.

4.8. In case of injury, poisoning or sudden illness, the victim must be provided with first (pre-medical) aid and, if necessary, his delivery to a healthcare facility must be organized.

4.9. If acid gets on the floor, it should be neutralized (sprinkled with soda or quicklime) and only then cleaned with a shovel and washed off with water. Clothes drenched in acid should be washed with plenty of water, neutralized with a 2-3% soda solution and replaced.

4.10. If any malfunction is detected that disrupts normal operation, it must be stopped. Inform your immediate supervisor of any observed shortcomings.

4.11. In the event of an accident, it is necessary to provide the victim with first aid, if necessary, call an ambulance, inform your immediate supervisor and keep the situation at the workplace unchanged until the investigation, unless it creates a threat to workers and does not lead to an accident.

5. OCCUPATIONAL SAFETY REQUIREMENTS AFTER WORK COMPLETION

5.1. Reduce the voltage of the test (measuring) installation to 0.

5.2. Disconnect the installation from the mains supply.

5.3. Ground the installation terminal.

5.4. Disconnect power supplies.

5.5. Report any shortcomings noticed during work to your immediate supervisor.

5.6. Take off protective clothing, put away personal protective equipment, protective clothing in the designated place.

5.7. Wash your face and hands with warm water and soap or take a shower.

Unified qualification directory for positions of managers, specialists and other employees (USC), 2019
Section “Qualification characteristics of positions of employees of nuclear energy organizations”
The section was approved by Order of the Ministry of Health and Social Development of the Russian Federation dated December 10, 2009 N 977

Head of Electrical Engineering Laboratory

Job responsibilities. Manages the electrical laboratory, ensuring the operation and repair of automation and relay protection equipment, control and measuring instruments of the relevant energy equipment, organizes the provision of equipment with the equipment and measuring instruments necessary for testing and monitoring its operation. Manages the ongoing and periodic monitoring of the operation of power plant equipment. Organizes setup, adjustment and ensures the normal operation of all devices, equipment and instruments under the jurisdiction of the laboratory, draws up instructions and instructions for their maintenance. Manages the preparation and participates in testing of equipment assigned to the laboratory. Monitors the timely registration of test results and maintenance of technical documentation. Monitors the condition of laboratory equipment and workplaces of laboratory workers, takes measures to eliminate deficiencies. Ensures the introduction of new equipment, the dissemination of advanced techniques and work methods in the laboratory. Monitors employees' compliance with labor protection, environmental protection, and fire safety rules.

Must know: laws and other regulatory legal acts of the Russian Federation, methodological and regulatory documents relating to the operation and repair of automation equipment, protection and instrumentation of relevant equipment; rules of technical operation, diagrams, operational characteristics and principles of operation of equipment of automatic devices, technological protections and instrumentation of the electrical laboratory; operational standards for equipment operation and testing; domestic and foreign experience in the field of electrical engineering laboratory activities; fundamentals of economics, organization of production, labor and management; basics of labor legislation; environmental regulations; labor protection and fire safety regulations; internal labor regulations.

Qualification requirements. Higher professional (technical) education and work experience in an electrical laboratory for at least 3 years (at a power plant for at least 5 years).